Feb 08 2017 we inspected vrm motor in every fourth nightly vibration and temperature parameters are in normal condition below 2mmsec and below 75 degrees but on january 21st we observed abnormal sound at motor de side so we inspected the bearing with vibration analyzerthere is a sudden rise in vibration 2mmsec to 6mmsec fluctuations are observed.